Time-optimized Radio Frequency pulse design within hardware and sequence constraints for multiband MRI

Student thesis: Doctoral ThesisDoctor of Philosophy

Abstract

Over the past few decades Magnetic Resonance Imaging (MRI) has become a clinically important medical imaging modality, thanks to its superior soft tissue contrast over computed tomography (CT), and the benefit of imaging deep anatomies which is challenging with ultrasound technology. In addition, unlike CT and PET it does not make use of ionizing radiation. This makes MRI well-suited for at-risk patient populations, as well as an indispensable modality for healthcare research.
Unfortunately MRI is also expensive, largely due to the cost of hardware involved and its maintenance. Adding to this problem, MR acquisition times are typically longer than comparable CT examinations, which can make MRI scans uncomfortable experiences, and economically speaking decreases patient throughput. Both of these disadvantages are addressed by reducing MR scan durations, where parallel imaging methods such as SENSE, GRAPPA and compressed sensing have had success in the past decade. Acceleration in parallel imaging however comes at a cost in signal-to-noise ratio (SNR) as MR images are formed from undersampled data.
Multiband techniques (a.k.a. Simultaneous Multi-Slice) reduce scan time by exciting and acquiring signal from multiple slices simultaneously, and consequently using multiple receiver coils for unfolded reconstruction. This type of acceleration has an SNR benefit over parallel imaging, for a fixed echo-time, as when no in-plane undersampling is used the SNR cost is solely due to multi-channel reconstruction. However challenges in multiband imaging arise in the design of multiband RF pulses, which can take significantly longer to transmit and consequently lead to lower acquired signal, due to relaxation. Exciting multiple slices also places significant demand on current hardware, in terms of coping with higher RF power, and higher frequency demands for both RF and gradient systems. Up-grading hardware is not always an option, due to the cost involved. In addition, higher RF power requirements for exciting multiple slices can also lead to increased patient heating, measured as specific absorption rate (SAR), which needs to be considered for MRI safety.
The work presented in this thesis seeks to improve multiband RF pulse design techniques by three means; firstly, we demonstrate practical hardware considerations for implementing time-optimized multiband pulses. This includes considerations for RF transmission hardware for phase-optimized, time-shifted and root-flipped multiband RF pulses, as well as gradient hardware considerations for using time-variable selection gradients, which have been shown to greatly enhance multiband RF performance. Based on such considerations, we propose the use of amplitude modulated multiband RF pulses, as well as the design of time-variable gradient waveforms with smooth shapes, which significantly reduce demands on MR hardware when necessary.
Secondly, time-shifted and root-flipped multiband pulses can have misaligned spin-echo
signals for different slices, which can lead to different T2 and T2∗ contrast; these effects have been investigated and discussed.
Thirdly, using the hardware considerations we have implemented multiband RF pulses with time-variable selection gradients in a cardiac bSSFP sequence, one of the most clinically relevant examinations of our time. Although the shortest RF pulses are thought to be optimal for rapid MR, they do not directly lead to the shortest acquisition time due to patient heating, as this is limited by SAR. We reformulated the RF pulse design problem to reduce image acquisition duration directly which can result in shorter breath-hold periods and improved image quality.
Date of Award2019
Original languageEnglish
Awarding Institution
  • King's College London
SupervisorShaihan Malik (Supervisor) & Jo Hajnal (Supervisor)

Cite this

'