TY - CHAP
T1 - Deep Learning for Low-Field to High-Field MR
T2 - 2nd International Workshop on Machine Learning for Medical Image Reconstruction, MLMIR 2019 held in Conjunction with 22nd International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2019
AU - Lin, Hongxiang
AU - Figini, Matteo
AU - Tanno, Ryutaro
AU - Blumberg, Stefano B.
AU - Kaden, Enrico
AU - Ogbole, Godwin
AU - Brown, Biobele J.
AU - D’Arco, Felice
AU - Carmichael, David W.
AU - Lagunju, Ikeoluwa
AU - Cross, Helen J.
AU - Fernandez-Reyes, Delmiro
AU - Alexander, Daniel C.
PY - 2019/1/1
Y1 - 2019/1/1
N2 - MR images scanned at low magnetic field (< 1 T) have lower resolution in the slice direction and lower contrast, due to a relatively small signal-to-noise ratio (SNR) than those from high field (typically 1.5T and 3T). We adapt the recent idea of Image Quality Transfer (IQT) to enhance very low-field structural images aiming to estimate the resolution, spatial coverage, and contrast of high-field images. Analogous to many learning-based image enhancement techniques, IQT generates training data from high-field scans alone by simulating low-field images through a pre-defined decimation model. However, the ground truth decimation model is not well-known in practice, and lack of its specification can bias the trained model, aggravating performance on the real low-field scans. In this paper we propose a probabilistic decimation simulator to improve robustness of model training. It is used to generate and augment various low-field images whose parameters are random variables and sampled from an empirical distribution related to tissue-specific SNR on a 0.36T scanner. The probabilistic decimation simulator is model-agnostic, that is, it can be used with any super-resolution networks. Furthermore we propose a variant of U-Net architecture to improve its learning performance. We show promising qualitative results from clinical low-field images confirming the strong efficacy of IQT in an important new application area: epilepsy diagnosis in sub-Saharan Africa where only low-field scanners are normally available.
AB - MR images scanned at low magnetic field (< 1 T) have lower resolution in the slice direction and lower contrast, due to a relatively small signal-to-noise ratio (SNR) than those from high field (typically 1.5T and 3T). We adapt the recent idea of Image Quality Transfer (IQT) to enhance very low-field structural images aiming to estimate the resolution, spatial coverage, and contrast of high-field images. Analogous to many learning-based image enhancement techniques, IQT generates training data from high-field scans alone by simulating low-field images through a pre-defined decimation model. However, the ground truth decimation model is not well-known in practice, and lack of its specification can bias the trained model, aggravating performance on the real low-field scans. In this paper we propose a probabilistic decimation simulator to improve robustness of model training. It is used to generate and augment various low-field images whose parameters are random variables and sampled from an empirical distribution related to tissue-specific SNR on a 0.36T scanner. The probabilistic decimation simulator is model-agnostic, that is, it can be used with any super-resolution networks. Furthermore we propose a variant of U-Net architecture to improve its learning performance. We show promising qualitative results from clinical low-field images confirming the strong efficacy of IQT in an important new application area: epilepsy diagnosis in sub-Saharan Africa where only low-field scanners are normally available.
UR - http://www.scopus.com/inward/record.url?scp=85076223527&partnerID=8YFLogxK
U2 - 10.1007/978-3-030-33843-5_6
DO - 10.1007/978-3-030-33843-5_6
M3 - Conference paper
AN - SCOPUS:85076223527
SN - 9783030338428
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 58
EP - 70
BT - Machine Learning for Medical Image Reconstruction - 2nd International Workshop, MLMIR 2019, held in Conjunction with MICCAI 2019, Proceedings
A2 - Knoll, Florian
A2 - Maier, Andreas
A2 - Rueckert, Daniel
A2 - Ye, Jong Chul
PB - SPRINGER
Y2 - 17 October 2019 through 17 October 2019
ER -