T1 - PET/MR synchronization by detection of switching gradients
AU - Weissler, Bjoern
AU - Gebhardt, Pierre
AU - Lerche, Christoph W.
AU - Soultanidis, Georgios M.
AU - Wehner, Jakob
AU - Heberling, Dirk
AU - Schulz, Volkmar
PY - 2015/6/1
Y1 - 2015/6/1
N2 - The full potential of simultaneous Positron Emission Tomography (PET) and Magnetic Resonance Imaging (MRI) acquisition, such as dynamic studies or motion compensation, can only be explored if the data of both modalities is temporally synchronized. As such hybrid imaging systems are commonly realized as custom-made PET inserts for commercially available MRI scanner, a synchronization solution has to be implemented (depending on the vendor of the MRI system). In contrast, we demonstrate a simple method for temporal synchronization, which does not require a connection to the MRI. It uses the normally undesired effect of induced voltages on the PET electronics from switching MRI gradients. The electronic circuit needs very few components and the gradient pick-up coils are made from PCB traces and vias on the PET detector boards. Neither programming the MRI nor any physical connection to the MR scanner is needed, thus avoiding electromagnetic compatibility problems. This method works inherently with most MRI sequences and is a vendor- independent solution. A characterization of the sensors in an MRI scanner showed that the MRI gradients are detected with a precision of 120μs (with the current implementation). Using different trigger thresholds, it is possible to trigger selectively on certain MRI sequences, depending on their gradient slew rate settings. Timings and pulse diagrams of MRI sequences can be recognized from the generated data. The method was successfully used for temporal alignment between PET and MRI in an MRI-based PET-motion-compensation application.
AB - The full potential of simultaneous Positron Emission Tomography (PET) and Magnetic Resonance Imaging (MRI) acquisition, such as dynamic studies or motion compensation, can only be explored if the data of both modalities is temporally synchronized. As such hybrid imaging systems are commonly realized as custom-made PET inserts for commercially available MRI scanner, a synchronization solution has to be implemented (depending on the vendor of the MRI system). In contrast, we demonstrate a simple method for temporal synchronization, which does not require a connection to the MRI. It uses the normally undesired effect of induced voltages on the PET electronics from switching MRI gradients. The electronic circuit needs very few components and the gradient pick-up coils are made from PCB traces and vias on the PET detector boards. Neither programming the MRI nor any physical connection to the MR scanner is needed, thus avoiding electromagnetic compatibility problems. This method works inherently with most MRI sequences and is a vendor- independent solution. A characterization of the sensors in an MRI scanner showed that the MRI gradients are detected with a precision of 120μs (with the current implementation). Using different trigger thresholds, it is possible to trigger selectively on certain MRI sequences, depending on their gradient slew rate settings. Timings and pulse diagrams of MRI sequences can be recognized from the generated data. The method was successfully used for temporal alignment between PET and MRI in an MRI-based PET-motion-compensation application.
KW - Magnetic resonance imaging
KW - molecular imaging
KW - PET-MR
KW - positron emission tomography
KW - synchronization
UR - http://www.scopus.com/inward/record.url?scp=84933529576&partnerID=8YFLogxK
U2 - 10.1109/TNS.2015.2427995
DO - 10.1109/TNS.2015.2427995
M3 - Article
AN - SCOPUS:84933529576
SN - 0018-9499
VL - 62
SP - 650
EP - 657
JO - IEEE Transactions on Nuclear Science
JF - IEEE Transactions on Nuclear Science
IS - 3
M1 - 7123013
ER -