Tissue Doppler-Derived Left Ventricular Systolic Velocity Is Associated with Lethal Arrhythmias in Cardiac Device Recipients Irrespective of Left Ventricular Ejection Fraction

Mohamad F. Barakat, Omar Chehab, Amit Kaura, Nicholas Sunderland, Sajad Hayat, Para S. Dhillon, Nick Gall, Mark J. Monaghan, George Amin-Youssef, Jamil Mayet, Ajay M. Shah, Paul A. Scott, Darlington O. Okonko*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Background: Life-threatening arrhythmias (LTAs) can trigger sudden cardiac death or provoke implantable cardioverter-defibrillator (ICD) discharges that escalate morbidity and mortality. Longitudinal myofibrils predominate in the subendocardium, which is uniquely sensitive to arrhythmogenic triggers. In this study, we test the hypothesis that mitral annular systolic velocity (S′), a simple routinely obtained tissue Doppler index of LV long-axis systolic function, might predict lethal arrhythmias irrespective of left ventricular ejection fraction (LVEF). Methods: This is a retrospective analysis of data from 302 patients (mean age, 68 years; LVEF, 32%; 77% male; 52% ischemic; 35% primary prevention; and 53% cardiac resynchronization therapy defibrillator [CRT-D]) who were followed up (median, 15 months) at two centers after receipt of an ICD or CRT-D for diverse indications. S′, averaged from tissue Doppler-derived medial and lateral mitral annular velocities, was correlated with the primary outcome of time to sustained ventricular tachycardia (VT) or fibrillation (VF) needing device therapy. Results: The median S′ was 5.1 (interquartile range, 4.0-6.2) cm/sec and lower in CRT-D than ICD subjects (4.5 [3.8-5.6] cm/sec vs 5.5 [4.8-6.8] cm/sec, P < .001). Fifty-six (19%) subjects had LTA. Each 1 cm/sec higher S′ correlated to a 30% decreased risk of LTA (hazard ratio = 0.70; 95% CI, 0.57-0.87; P = .001) independently of age, sex, β-blocker use, center, ICD use, and LVEF. Adding S′ to the baseline Cox model improved net reclassification (P = .02). An S′ > 5.6 cm/sec was the best cutoff and linked to a 58% lower LTA risk than an S′ ≤ 5.6 cm/sec (95% CI, 0.23-0.85; P = .02). Conclusions: A higher S′ is associated with a reduced probability of LTA in cardiac device recipients irrespective of LVEF and may have the potential to be used clinically to titrate medical, device, and ablative therapies to mitigate future arrhythmic risk.

Original languageEnglish
Pages (from-to)1509-1516
Number of pages8
JournalJournal of The American Society of Echocardiography
Volume33
Issue number12
DOIs
Publication statusPublished - Dec 2020

Keywords

  • Cardiomyopathy
  • Sudden cardiac death
  • Tissue Doppler imaging
  • Ventricular arrhythmia

Fingerprint