Ultrabubble: A Laminated Ultrasound Contrast Agent with Narrow Size Range

Pei-Lun Lin, Robert Eckersley, Elizabeth A. H. Hall

Research output: Contribution to journalArticlepeer-review

76 Citations (Scopus)

Abstract

A laminated shell microcapsule is described resisting aggregation and withstanding ultrasound destruction, showing a good backscatter signal, as shown in the figure. Templated synthesis produces versatile monodisperse capsules <3 mu m, with ultrasound-pressure dependency allowing rupture above MI similar to 1.5 (at 2 MHz), suitable for future development as both controlled-delivery agent and contrast agent.

Original languageEnglish
Pages (from-to)3949-52
Number of pages4
JournalADVANCED MATERIALS
Volume21
Issue number38-39
DOIs
Publication statusPublished - 19 Oct 2009