TY - JOUR
T1 - Design, synthesis and properties of novel iron(III)-specific fluorescent probes
AU - Luo, W
AU - Ma, Y M
AU - Quinn, P J
AU - Hider, R C
AU - Liu, Z D
PY - 2004/4
Y1 - 2004/4
N2 - Bidentate chelators such as hydroxypyridinones and hydroxypyramones are highly iron selective. The synthesis of two novel fluorescent probes N-[2-(3-hydroxy-2-methyl-4-oxopyridin-1(4H)-yl)ethyl]2-(7-methoxy-2-oxo- 2H-chromen-4-yl)acetamide (CP600) and N-[(3-hydroxy-6-methyl-4-oxo-4H-pyran-2-yl)methyl]-2-(7-methoxy-2-oxo-2H -chromen-4-yl)acetamide (CP610) is reported. The method involves coupling the bidentate ligands, 3-hydroxypyridin-4-one and 3-hydroxypyran-4-one, with the well-characterised fluorescent probe methoxycoumarin. Fluorescence emission of both probes at 380 nm is readily quenched by Fe3+. The fluorescence was quenched to a greater extent by Fe3+ than by Mn2+, Co2+, Zn2+, Ca2+, Mg2+, Na+ and K+ and to approximately the same extent as Cu2+. Comparison of the fluorescence-quenching ability by a range of metal ions on CP600 and CP610 and the hexadentate chelator, calcein, under in-vitro conditions, demonstrated advantages of the two novel fluorescent probes with respect to both iron(III) sensitivity and selectivity. Chelation of iron(III) by CP600 and CP610 leads to the formation of a complex with a metal-to-ligand ratio of 1:3. Fluorescence is quenched on formation of such complexes. These probes possess a molecular weight less than 400 and thus they are predicted to permeate biological membranes by passive diffusion, and have potential for reporting intracellular organelle labile iron levels.
AB - Bidentate chelators such as hydroxypyridinones and hydroxypyramones are highly iron selective. The synthesis of two novel fluorescent probes N-[2-(3-hydroxy-2-methyl-4-oxopyridin-1(4H)-yl)ethyl]2-(7-methoxy-2-oxo- 2H-chromen-4-yl)acetamide (CP600) and N-[(3-hydroxy-6-methyl-4-oxo-4H-pyran-2-yl)methyl]-2-(7-methoxy-2-oxo-2H -chromen-4-yl)acetamide (CP610) is reported. The method involves coupling the bidentate ligands, 3-hydroxypyridin-4-one and 3-hydroxypyran-4-one, with the well-characterised fluorescent probe methoxycoumarin. Fluorescence emission of both probes at 380 nm is readily quenched by Fe3+. The fluorescence was quenched to a greater extent by Fe3+ than by Mn2+, Co2+, Zn2+, Ca2+, Mg2+, Na+ and K+ and to approximately the same extent as Cu2+. Comparison of the fluorescence-quenching ability by a range of metal ions on CP600 and CP610 and the hexadentate chelator, calcein, under in-vitro conditions, demonstrated advantages of the two novel fluorescent probes with respect to both iron(III) sensitivity and selectivity. Chelation of iron(III) by CP600 and CP610 leads to the formation of a complex with a metal-to-ligand ratio of 1:3. Fluorescence is quenched on formation of such complexes. These probes possess a molecular weight less than 400 and thus they are predicted to permeate biological membranes by passive diffusion, and have potential for reporting intracellular organelle labile iron levels.
UR - http://www.scopus.com/inward/record.url?scp=1842575919&partnerID=8YFLogxK
U2 - 10.1211/0022357023196
DO - 10.1211/0022357023196
M3 - Article
VL - 56
SP - 529
EP - 536
JO - Journal of Pharmacy and Pharmacology
JF - Journal of Pharmacy and Pharmacology
IS - 4
ER -