T1 - Interventional digital tomosynthesis from a standard fluoroscopy system using 2D-3D registration
AU - Alhrishy, Mazen
AU - Varnavas, Andreas
AU - Carrell, Tom
AU - King, Andrew
AU - Penney, Graeme
PY - 2014/10/16
Y1 - 2014/10/16
N2 - Interventional fluoroscopy provides guidance in a variety of minimally invasive procedures. However, three-dimensional (3D) clinically relevant information is projected onto a two-dimensional (2D) image which can make image interpretation difficult. Moreover, vasculature visualisation requires the use of iodinated contrast media which is nephrotoxic and is the primary cause of renal complications. In this article, we demonstrate how digital tomosynthesis slices can be produced on standard fluoroscopy equipment by registering the preoperative CT volume and the intraoperative fluoroscopy images using 2D-3D image registration. The proposed method automatically reconstructs patient-anatomy-specific slices and removes clutter resulting from bony anatomy. Such slices could provide additional intraoperative information which cannot be provided by the preoperative CT volume alone, such as the deformed aorta position offering improved guidance precision. Image acquisition would fit with interventional clinical work-flow and would not require a high X-ray dose. Experiments are carried out using one phantom and four clinical datasets. Phantom results showed a 3351% contrast-to-noise improvement compared to standard fluoroscopy. Patient results showed our method enabled visualization of clinically relevant features: outline of the aorta, the aortic bifurcation and some aortic calcifications.
AB - Interventional fluoroscopy provides guidance in a variety of minimally invasive procedures. However, three-dimensional (3D) clinically relevant information is projected onto a two-dimensional (2D) image which can make image interpretation difficult. Moreover, vasculature visualisation requires the use of iodinated contrast media which is nephrotoxic and is the primary cause of renal complications. In this article, we demonstrate how digital tomosynthesis slices can be produced on standard fluoroscopy equipment by registering the preoperative CT volume and the intraoperative fluoroscopy images using 2D-3D image registration. The proposed method automatically reconstructs patient-anatomy-specific slices and removes clutter resulting from bony anatomy. Such slices could provide additional intraoperative information which cannot be provided by the preoperative CT volume alone, such as the deformed aorta position offering improved guidance precision. Image acquisition would fit with interventional clinical work-flow and would not require a high X-ray dose. Experiments are carried out using one phantom and four clinical datasets. Phantom results showed a 3351% contrast-to-noise improvement compared to standard fluoroscopy. Patient results showed our method enabled visualization of clinically relevant features: outline of the aorta, the aortic bifurcation and some aortic calcifications.
KW - 2D-3D image registration
KW - Endovascular aneurysm repair
KW - Interventional digital tomosynthesis
UR - http://www.scopus.com/inward/record.url?scp=84922826178&partnerID=8YFLogxK
U2 - 10.1016/j.media.2014.10.001
DO - 10.1016/j.media.2014.10.001
M3 - Article
AN - SCOPUS:84922826178
SN - 1361-8415
VL - 19
SP - 137
EP - 148
JO - Medical Image Analysis
JF - Medical Image Analysis
IS - 1
ER -