Medium-term cost-effectiveness of an automated non-invasive ventilation outpatient set-up versus a standard fixed level non-invasive ventilation inpatient set-up in obese patients with chronic respiratory failure: a protocol description

S. Mandal, G. Arbane, P. Murphy, M. W. Elliott, J. P. Janssens, J. L. Pepin, J. F. Muir, A. Cuvelier, M. Polkey, D. Parkin, A. Douiri, N. Hart

Research output: Contribution to journalArticlepeer-review

15 Citations (Scopus)

Abstract

Introduction: Obesity is an escalating issue, with an accompanying increase in referrals of patients with obesity-related respiratory failure. Currently, these patients are electively admitted to hospital for initiation of non-invasive ventilation (NIV), but it is unknown whether outpatient initiation is as effective as inpatient set-up. We hypothesise that outpatient set-up using an autotitrating NIV device will be more cost-effective than a nurse-led inpatient titration and set-up.

Methods and analysis: We will undertake a multinational, multicentre randomised controlled trial. Participants will be randomised to receive the usual inpatient set-up, which will include nurse-led initiation of NIV or outpatient set-up with an automated NIV device. They will be stratified according to the trial site, gender and previous use of NIV or continuous positive airway pressure. Assuming a 10% dropout rate, a total sample of 82 patients will be required. Cost-effectiveness will be evaluated using standard treatment costs and health service utilisation as well as health-related quality of life measures (severe respiratory insufficiency (SRI) and EuroQol-5 dimensions (EQ-5D)). A change in the SRI questionnaire will be based on the analysis of covariance adjusting for the baseline measurements between the two arms of patients.

Ethics and dissemination: This study has been approved by the Westminster National Research Ethics Committee (11/LO/0414) and is the trial registered on the UKCRN portfolio. The trial is planned to start in January 2015 with publication of the trial results in 2017.
Original languageEnglish
Article numbere007082
Number of pages7
JournalBMJ open
Volume5
Issue number4
DOIs
Publication statusPublished - 23 Apr 2015

Fingerprint

Dive into the research topics of 'Medium-term cost-effectiveness of an automated non-invasive ventilation outpatient set-up versus a standard fixed level non-invasive ventilation inpatient set-up in obese patients with chronic respiratory failure: a protocol description'. Together they form a unique fingerprint.

Cite this